Chest Compression Depth and Rate - Effect on Instructor Visual Assessment of Chest Compression Quality

( Max 2000 Items )
URI http://shark.lib.kagawa-u.ac.jp/kuir/metadata/28680
Title
Chest Compression Depth and Rate - Effect on Instructor Visual Assessment of Chest Compression Quality
File
Description

Abstract
BACKGROUND:

The aim of the present study was to determine whether instructors could accurately assess chest compression quality visually, considering the association between chest compression depth and rate. Methods and Results: In this prospective, observational study, the quality of chest compressions performed by a simulated actor in a video was visually assessed by certified instructors. The film consisted of 14 case scenarios, each including a combination of depth (2 patterns: adequate, 5-6 cm; and inadequate, <5 cm) and rate (7 categories: compressions 90-150 times/min in increments of 10 times/min). The participants evaluated whether the compression depth was adequate, deep, or inadequate; and whether the compression rate was appropriate, fast, or slow. Of 198 instructors, 56% of participants misidentified adequate depth as deep at a chest compression rate of 120/min (the tendency toward this response increased as chest compression rate increased), and 64.1% of participants incorrectly determined 130/min to be appropriate. On generalized linear mixed-effects model analysis, perceived chest compression depth and rate were significant factors for a correct response (P<0.01, both). A significant interaction between chest compression depth and rate was observed (P<0.01).
CONCLUSIONS:

In the visual assessment of chest compression quality, recognition of chest compression depth was closely associated with compression rate. Misidentification of adequate chest compression depth as deep increased as the compression rate increased.

KEYWORDS:

Basic science; Cardiopulmonary resuscitation; Chest compression resuscitation

(医博甲720)

Author
著者 永渕 克弥
著者(ヨミ) ナガフチ カツヤ
著者(別表記) Nagafuchi Katsuya
Publication Title
Circulation Journal
Volume
83
Issue
2
Start Page
418
End Page
423
Publisher
Japanese Circulation Society
日本循環器学会
Publisher Aalternative
日本循環器学会
Published Date
2018-12-29
ISSN
1346-9843
NCID
AA11591968
PMID
30606940
DOI
10.1253/circj.CJ-18-0952
Resource Type
Thesis or Dissertation
Language
eng
Relation
出版社版DOIリンク(URL): https://doi.org/10.1253/circj.CJ-18-0952
Resource URL
https://doi.org/10.1253/circj.CJ-18-0952
Relation(isVersionOf)
Publisher's Version.
Rights
"This is the Publisher's version of the following article: Chest Compression Depth and Rate - Effect on Instructor Visual Assessment of Chest Compression Quality; Circulation Journal;Volume 83 Number 2 (2019) 418-423; doi: 10.1253/circj.CJ-18-0952, which has been published in final form at https://doi.org/10.1253/circj.CJ-18-0952 . "
© 2019 THE JAPANESE CIRCULATION SOCIETY